TOP FIRE PUMP SUPPLIER IN UAE
In the realm of fire protection systems, the Fire Pump Set plays a pivotal role. Designed with the sprinkler system in mind, it ensures a continuous supply of water or fire retardants from a storage tank to the sprinkler system. Often regarded as the heart of the fire protection system, selecting the right Fire Pump Set is paramount. Fire pump supplier
When a fire emergency strikes and the fire alarm system is triggered, the fire pump springs into action. It draws water from a designated storage tank or another approved source. This water is then distributed at high pressure through an intricate network of pipes, ready to be dispensed onto the fire. Fire pump supplier
In situations where the water supply lacks sufficient pressure to meet the hydraulic design specifications of the fire prevention system, the use of fire pumps becomes necessary. This scenario typically arises when a system demands a relatively high terminal pressure at the fire sprinkler to facilitate the flow of a significant volume of water. Such situations can occur in storage warehouses with extensive fire protection needs or in the case of very tall buildings, like high-rise structures. Additionally, when the water supply is sourced from a below-ground storage tank, the installation of fire pumps is also mandated. Fire pumps play a critical role in ensuring that fire protection systems function effectively in these challenging conditions, guaranteeing the safety of occupants and property. Fire pump supplier
The activation of a Fire Pump Set occurs when it detects a drop in pressure below a specific set point within the Fire Sprinkler System. This drop in pressure typically occurs when a fire event is detected, signaling the need for an immediate water supply to the sprinkler system to effectively combat the fire. Fire pump supplier
For added safety and reliability, some fire pump systems incorporate two pumps: the Duty Pump and the Standby Pump. The Duty Pump serves as the primary pump and activates when pressure decreases, ensuring a swift response to the fire emergency. Concurrently, the Standby Pump remains on standby, ready to take over if the Duty Pump encounters any issues or requires maintenance.
To further ensure uninterrupted functionality, the Fire Pump Set is often connected to a separate generator or the nearest electrical sub-station. This connection is established to ensure that the fire pump system functions correctly even in the event of a power failure, a critical feature for continuous fire protection during adverse conditions.
End suction fire pumps are versatile and cost-effective. They feature a single-suction impeller and are commonly used in smaller fire protection systems, including residential and small commercial buildings. Fire pump supplier
Vertical split-case fire pumps are similar to their horizontal counterparts but are vertically oriented. They are often used in situations where space is a constraint, such as high-rise buildings and compact mechanical rooms. Fire pump supplier
Vertical in-line fire pumps have a compact design and are installed within the piping system, saving space and simplifying installation. They are ideal for buildings with limited mechanical room space. Fire pump supplier
Horizontal split-case fire pumps are commonly used in fire protection systems. They are known for their efficiency and ease of maintenance. These pumps have a horizontally split casing, making them suitable for various applications. Fire pump supplier
Vertical turbine fire pumps are submerged in a water source, such as a well or reservoir. They are commonly used in areas with below-ground water sources, like underground storage tanks. Fire pump supplier
TOP FIRE PUMP SUPPLIER IN UAE
Fire pump supplier
Casing Cast Iron / Ductile Iron
Impeller Bronze / Duplex (upon request)
Shaft Alloy Steel / Stainless Steel / Duplex (upon request)
Capacity 50GPM to 1000 GPM
Pressure 65 to 234 PSI
Max. Working Pressure 180 to 315 PSI
Speed 2900, 3000, 3500 and 3600 RPM
Fire pump supplier
Casing Cast Iron / Ductile Iron, Impeller Bronze / Duplex (upon request) , Shaft Alloy Steel / Stainless Steel / Duplex (upon request)
Capacity 150GPM to 3500 GPM , Pressure 88 to 335 PSI , Max. Working Pressure 220 to 410 PSI, Speed 2900, 3000, 3500 and 3600 RPM
Fire pump supplier
Capacity 200GPM to 2000 GPM, Pressure 40 to 359 PSI, Max. Working Pressure 290 to 395 PSI, Speed 1450, 1480, 1760, 1780, 2900, 2980, 2950 & 3000 RPM
In the competitive landscape of engine-driven centrifugal fire pump skids, AL ADRAN stands tall as your premium choice. We understand the critical importance of fire protection and have specialized in delivering top-notch packages that align with NFPA 20 requirements, boasting Listed & Approved Drivers for unparalleled performance. Fire pump supplier
When it comes to safeguarding your property against the ravages of fire, compromise is not an option. AL ADRAN proudly offers a range of listed centrifugal fire pump skids designed to cater to every fire protection need. With us, your safety is our priority.
Our centrifugal fire pump skids are driven by Listed & Approved Diesel Engines and Electric Motors. These powerhouses ensure optimal reliability and efficiency, guaranteeing that your fire protection system performs at its peak when you need it most.
Before our skid packages reach your hands, they undergo meticulous pre-testing and thorough inspections. We leave no room for error, ensuring that every component is in perfect working order. Your peace of mind is our commitment.
Our skid packages are not just assembled; they are masterfully crafted for precision. The alignment of the pump with the diesel engine or electric motor is flawless, ensuring direct and seamless operation. Downtime is not in our vocabulary.
At the core of our skid packages lies a one-piece base plate, complete with anchor bolt holes. This design choice enhances stability, ensuring that your fire protection system remains steadfast in the face of adversity.
Our skid packages are constructed using engineered, coated, hot-rolled mild steel, providing resistance against corrosion and abrasion. Additionally, a heavy fabricated C-Channel Structure ensures the perfect alignment of the pump with the diesel engine or electric motor.
In today's world, space is a valuable commodity. AL ADRAN's skid packages feature a compact design with a minimal footprint, ideal for retrofitting into existing facilities. No need to sacrifice space for safety.
All steel above ground tanks for flammable and combustible
liquid are assembled and tested to all requirements as follows
ANSI/UL-142-Complaint. Installation standard compliance to NFPA 30, NFPA30A and NFPA31 Fire pump supplier
Primary Containment Tanks: Horizontal Cylindrical Construction (Capacity upto 75000 Gallon) Vertical Cylindrical
All steel above ground tanks for flammable and combustible
liquid are assembled and tested to all requirements as follows
ANSI/UL-142-Complaint. Installation standard compliance to NFPA 30, NFPA30A and NFPA31 Fire pump supplier
Primary Containment Tanks: Horizontal Cylindrical Construction (Capacity upto 75000 Gallon) Vertical Cylindrical Construction (Capacity upto 60000 Gallon) Rectangular Construction (Capacity upto 550 Gallon) Secondary Containment Tanks Horizontal Cylindrical Construction (Capacity upto 75000 Gallon) Vertical Cylindrical Construction (Capacity upto 60000 Gallon)
Jockey pumps are small, motor driven pumps used in conjunction with
main fire pumps to compensate for minor leaks in the fire protection
system and automatically maintain stand-by pressure. This reduces
wear on the main pump and controller caused by unnecessary,
frequent operation. Jockey Pump controllers are available for across
the-line starting. Fire pump supplier
Fire pump supplier
All Fire Pump Controllers are factory assembled, wired, tested as a
unit and comply with all requirements of the latest edition of NFPA-
20 (Centrifugal Fire Pumps) and NFPA-70 (National Electrical Code).
Controllers are listed by Underwriters
Fire pump supplier
All Fire Pump Controllers are factory assembled, wired, tested as a
unit and comply with all requirements of the latest edition of NFPA-
20 (Centrifugal Fire Pumps) and NFPA-70 (National Electrical Code).
Controllers are listed by Underwriters Laboratories, Inc., in accordance
with UL218, Standard for Fire Pump Controllers, CSA, and Standard
for Industrial Control Equipment (CUL) and approved by Factory Mutual (FM). All controllers are Y2K compliant. This component plays a vital role in operation of fire pumps as it controls the entire system. It is selected as per customer choice if any, otherwise it can be either TORNATECH, OR EATON.
Looking for a dependable NAFFCO fire pump supplier? Our experts provide high-quality fire pumps and equipment, ensuring your safety. Contact us today
Note: Fire pump sets are available for other duty points and higher ranges as well.
This website uses cookies. By continuing to use this site, you accept our use of cookies.